QuantiGene™ Singleplex Assay Kit

The QuantiGene Singleplex Assay is comprised of three modules:
• QuantiGene Singleplex Assay Kit
• QuantiGene Singleplex target-specific probe sets (sold separately)
• QuantiGene Sample Processing Kit (sold separately) (not required for purified RNA samples)
Features of the QuantiGene Singleplex Assay include:
• Direct from lysate quantitation using signal amplification—no RNA or DNA purification, reverse transcription, or PCR amplification needed
• Precisely quantify subtle differences in gene expression as small as 10%
• Simple workflow features lyse-and-go sample preparation, easily automatable ELISA-like protocol, and readout using any standard luminometer
• Analyze any sample type: cultured cells; whole blood or dried blood spots; fresh, frozen, or formalin-fixed paraffin-embedded (FFPE) tissues; plants; bacteria
QuantiGene Singleplex assays bring the power of branched DNA (bDNA) technology to basic and pre-clinical research. The bDNA assay is a sandwich nucleic acid hybridization method that uses bDNA molecules to amplify signal from captured target RNA. bDNA technology forms the basis of the FDA-approved clinical diagnostic VERSANT 3.0 assays for HIV, HCV, and HBV viral load that are offered commercially by Siemens and have been in use for over a decade. Another advantage of bDNA assays is that RNA is measured directly from the sample source, without RNA purification or enzymatic manipulation, thereby avoiding inefficiencies and variability introduced by or errors inherent to these processes.
Each capture plate in this assay kit is packaged individually in a sealed foil pouch.
Specifications
Format
96-well
For Use With (Application)
QuantiGene Singleplex Probe Set
For Use With (Equipment)
Luminometer
Content And Storage
• Blocking Reagent (400 μL, store at 2–8°C)
• Pre-Amplifier Solution (25 mL, store at 2–8°C)
• Amplifier Solution (25 mL, store at 2–8°C)
• Capture Plate (2 ea, packaged individually, store at 2–8°C)
• Label Probe (24 μL, store at 2–8°C)
• Substrate (24 mL, store at 2–8°C)
• Label Probe Diluent (25 mL, store at 15–30°C)
• Lysis Mixture (18 mL, store at 15–30°C)
• Wash Buffer Component 1 (3 mL, store at 15–30°C)
• Wash Buffer Component 2 (5 mL, store at 15–30°C)
• Plate Seals Day 1 (2 ea, store at 15–30°C)
• Plate Seals Day 2 (10 ea, store at 15–30°C)
Product Line
QuantiGene Singleplex
Product Type
Singleplex Assay Kit
Quantity
2 Plates
Detection Method
Chemiluminescence
For Research Use Only. Not for use in diagnostic procedures.