Gas Generators and Accessories

Gas Generators and Accessories
- (2)
- (2)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (7)
- (1)
- (6)
- (3)
- (1)
- (1)
- (1)
- (1)
- (7)
Filtered Search Results

Parker domnick hunter™ Hydrogen Generators
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Research-grade hydrogen gas on demand
Outlet Port | 0.125 in. compression fitting |
---|---|
Height (Metric) | 45.6 cm |
Electrical Requirements | 90 to 264V 50/60Hz |
Warranty | 2 Years |
Depth (English) | 17.2 in. |
Width (English) | 13.5 in. |
Pressure | 0 to 100 psi |
Max. Ambient Operating Temperature | 5°C to 40°C |
Type | Hydrogen Fuel Gas Generator |
Nitrogen Purity | 99.9995% |
Depth (Metric) | 34.2 cm |
Voltage | 90 to 264 V |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, CSA, UL |
Weight (Metric) | 23 kg |
Height (English) | 17.9 in. |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas
High purity range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography.
Connections | 1/8 in. Compression |
---|---|
Outlet Port | compression fitting |
Height (Metric) | 45.6 cm |
Electrical Requirements | Universal (90V - 264V 50/60Hz) |
Outlet Size | 1/8 in. |
Warranty | 12 months on system, 24 months on PEM cell |
Outlet Pressure | 10 to 100 psig |
Depth (English) | 17 in. |
Width (English) | 13.5 in. |
For Use With (Application) | Gas chromatography, fuel gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Pressure | 10 to 100 psig |
Width (Metric) | 34.2 cm |
Includes | US, UK and EU power cord, Water drain tube, DI cartridge, User Guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Hydrogen Fuel Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 43.7 cm |
Voltage | 90-264 Universal Power Supply |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, CSA, cULus |
Weight (Metric) | 23 kg (Full of water) |
Height (English) | 18 in. |
Fisherbrand™ Ultra High Purity Hydrogen Gas Generators for GC Carrier and Fuel Gas
Ultra High Purity Range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography and fuel can carrier gas applications.
Connections | 1/8 in. Compression |
---|---|
Outlet Port | compression fitting |
Height (Metric) | 45.6 cm |
Electrical Requirements | Universal (90V - 264V 50/60Hz) |
Warranty | 12 months on system, 24 months on PEM cell |
Outlet Pressure | 10 to 100 psig |
Depth (English) | 18.5 in. |
Width (English) | 13.5 in. |
For Use With (Application) | Gas chromatography, fuel gas, carrier gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), nitrogen phosphorous detector carrier gas (NPD), thermal conductivity detector carrier gas (TCD), Electrolytic Conductivity Detector reactio |
Pressure | 10 to 100 psig |
Width (Metric) | 34.2 cm |
Includes | US, UK and EU power cord, Water drain tube, DI cartridge, User guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Hydrogen Carrier Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 47 cm |
Voltage | 90-264 Universal Power Supply |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, cULus |
Height (English) | 18 in. |
MilliporeSigma™ Supelco™ domnick hunter™ NITROX™ UHP Hydrogen Generator
A safe and economic alternative to high pressure gas cylinders
Type | Hydrogen Gas Generator |
---|---|
For Use With (Equipment) | Any Laboratory Instrument Requiring a Supply of Ultra High Purity Hydrogen |
Purity | 99.999% Pure Hydrogen |
For Use With (Application) | Carrier Gas and Fuel Gas Applications |
Parker domnick hunter™ Ultra-High Purity Hydrogen Generators for GC and GC/MS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ultra-high purity, low maintenance generators supply hydrogen for GC and GC/MS carrier gas applications, plus all commonly used combustion detectors used routinely in GC
Outlet Port | 0.125 in. compression fitting |
---|---|
Height (Metric) | 45.6 cm |
Electrical Requirements | 90 to 264V 50/60Hz |
Depth (English) | 18.5 in. |
Width (English) | 13.5 in. |
Purity | 99.9999% |
Pressure | 10 to 100 psi |
Max. Ambient Operating Temperature | 5°C to 40°C |
Type | Hydrogen Carrier Gas Generator |
Depth (Metric) | 47 cm |
Voltage | 90 to 264 V |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, CSA, UL |
Weight (Metric) | 25 kg |
Height (English) | 17.9 in. |
Restek™ Parker ChromGas™ Hydrogen Generators and Replacement Components
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
No high-pressure cylinders'more convenient and improved lab safety
Fisherbrand™ Ultra High Purity Hydrogen Gas Generators Accessory, Preventative Maintenance Kit
For use with Ultra High Purity Hydrogen Gas Generators for GC Carrier and Fuel Gas.
For Use With (Equipment) | Ultra High Purity Hydrogen Gas Generators For GC Carrier and Fuel Gas |
---|---|
For Use With (Application) | Gas chromatography, fuel gas, carrier gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), nitrogen phosphorous detector carrier gas (NPD), thermal conductivity detector carrier gas (TCD), Electrolytic Conductivity Detector reactio |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas Accessory, PM Kit
For use with High Purity Hydrogen Gas Generators for GC Fuel Gas.
For Use With (Equipment) | High Purity Hydrogen Gas Generators For GC Fuels |
---|---|
For Use With (Application) | Gas chromatography, fuel gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas Accessory, Desiccant Cartridge
For use with High Purity Hydrogen Gas Generators for GC Fuel Gas.
Restek™ Parker HydroGen Mate DI Water System
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Economical means of providing deionized water to hydrogen generators, or for other uses.
Restek™ Parker HydroGen Mate DI Water System Maintenance Kit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with Parker HydroGen Mate DI Water System.
Fisherbrand™ Zero Air Generators
Zero air gas generators provide a convenient and safe alternative to cylinder gas for gas chromatography combustion applications. These systems remove organic impurities from existing compressed air sources allowing the user to eliminate expensive bottled zero grade air from their lab.
Connections | 1.4 in. NPT (female) |
---|---|
Outlet Port | 1/4 in. NPT (female) |
Height (Metric) | 30 cm |
Outlet Size | 1/4 in. |
Warranty | 12 months on system |
Outlet Pressure | Up to 135 psig depending on inlet pressure |
Depth (English) | 3 in. |
Purity | Gas purity: <0.1ppm total hydrocarbon as CH4 |
For Use With (Application) | Gas chromatography, Flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Pressure | Varies with inlet. 5 psig less than inlet |
Width (Metric) | 25 cm |
Includes | US power cord, User guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Flow Rate | 1 L/min. |
Type | Zero Air Gas Generator |
Capacity | 1 L/min |
No. of FIDs | 2-3 |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 8 cm |
Frequency | 60 Hz |
Max. Inlet Air Temperature | 104°F |
Certifications/Compliance | CE, CSA, cULus |
Weight (Metric) | 3 kg |
Height (English) | 12 in. |
Fisherbrand™ Zero Air Generators For GC Fuels
Zero air generators produce a continuous stream of organic impurity-free air from external dry compressed air source and offer superior limits of detection over and above other modes of supply.
Outlet Port | compression fitting |
---|---|
Height (Metric) | 45.5 cm |
Warranty | 12 months on system |
Outlet Pressure | Up to 135 psig depending on inlet pressure |
Depth (English) | 16.7 in. |
Width (English) | 13.5 in. |
Purity | Gas purity: <0.1ppm total hydrocarbon as CH4 |
For Use With (Application) | Gas chromatography, Flame support gas, Flame ionization detector (GC-FID) Flame photometric detector (GC-FPD) |
Pressure | Varies with inlet. 5 psig less than inlet |
Width (Metric) | 34.2 cm |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Zero Air Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 42.5 cm |
Max. Inlet Air Temperature | 104°F |
Certifications/Compliance | CE, cULus |
Weight (Metric) | 14.2 kg |
Height (English) | 18 in. |
Restek™ Flammable Gas Flash Arrestor - Factory Mutual Approved
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Valve cuts off gas supply in the event of a flashback.
