Filtration Membrane Discs

Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (94)
- (8)
- (150)
- (9)
- (9)
- (4)
- (6)
- (173)
- (1)
- (2)
- (3)
- (22)
- (61)
- (43)
- (21)
- (89)
- (1)
- (1)
- (41)
- (14)
- (95)
- (5)
- (2)
- (1)
- (22)
- (2)
- (1)
- (3)
- (4)
- (4)
- (3)
- (11)
- (2)
- (41)
- (123)
- (50)
- (3)
- (20)
- (208)
- (45)
- (9)
- (24)
- (8)
- (82)
- (10)
- (20)
- (49)
- (1)
- (17)
- (2)
- (6)
- (1)
- (6)
- (1)
- (2)
- (12)
- (28)
- (1)
- (1)
- (2)
- (55)
- (5)
- (1)
- (1)
- (19)
- (1)
- (470)
- (143)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (277)
- (1)
- (2)
- (3)
- (140)
- (72)
- (61)
- (64)
Filtered Search Results

Material | MCE |
---|---|
For Use With (Application) | For all analytical, ultracleaning, and sterilizing applications at temperatures below 75°C (167°F) – except those involving esters, ether-alcohols, ketones, nitroparaffins or strong acids and bases. |
Autoclavable | Autoclavable |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.8 μm, Gridded

Mixed cellulose esters (MCE) membrane, hydrophilic

Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.8 μm |
Flow Rate | 190 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
No. per Case | 100Pack |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Pore Size | 10 μm |
---|---|
Flow Rate | 70 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | Nylon |
Filter Type | Net Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.22 μm

MF-Millipore™ Membrane Filter is a 13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic.

Pore Size | 0.22 μm |
---|---|
Disposable | Reusable |
Color | White |
Material | MCE |
Hydrophobicity | Hydrophilic |
Sterility | Non-sterile |
Thickness (Metric) | 150 μm |
Bubble Point | ≥3.52 bar, air with water |
Flow Rate | 18 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Gas Flow Rate | 2 L/min./cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm, Gridded

Mixed cellulose esters (MCE) membrane, hydrophilic

Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.45 μm |
Flow Rate | 60 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
No. per Case | 100Pack |
Quantity | 100/Pk. |
Material | MCE |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Membrane Type | Gridded |
Gas Flow Rate | 4 L/min/ cm2 |
MilliporeSigma™ Isopore™ Membrane Filters, 0.4 μm

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.

Type | Filter Membranes |
---|---|
Material | Polycarbonate |
Filter Type | Screen Filter |
MilliporeSigma™ Isopore™ Membrane Filters, 0.2 μm

Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.

Pore Size | 0.22 μm |
---|---|
Wettability | Hydrophilic |
Type | Filter Membranes |
Material | Polycarbonate |
Filter Type | Screen Filter |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ Durapore™ Membrane Filters, 0.22 μm

Recommended when maximum recovery is important. Durapore™ PVDF Membranes: 0.22μ Pore Size provide high flow rates and throughput, low extractables, broad chemical compatibility and low protein binding. Available in diameters ranging from 13mm to 142mm.

Pore Size | 0.22 μm |
---|---|
Type | Filter Membranes |
Color | White |
Material | PVDF |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Thickness (Metric) | 125 μm |
---|---|
Pore Size | 0.45 μm |
Bubble Point | 22 psi |
Flow Rate | >2.6 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | PVDF |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Nylon Membranes

Flexible and durable for easier handling. Cytiva Nylon Membranes are naturally hydrophilic, eliminating need for wetting agents and prewetting when filtering aqueous solutions.

Material | Nylon |
---|---|
Hydrophobicity | Hydrophilic |
Autoclavable | Autoclavable |
Cytiva Whatman™ 47 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ 47mm Nuclepore™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.

Flow Rate | High |
---|---|
Diameter (Metric) | 47 mm |
Material | Nucleopore Polycarbonate |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
Cytiva Whatman™ Mixed Cellulose Ester Membrane Filters
Whatman™ Mixed Cellulose Ester Membrane Filters are biologically inert and offers high degree of internal surface area for greater product adsorption.

Material | MCE |
---|---|
Autoclavable | Autoclavable |
Sterility | Sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.65 μm

MF-Millipore™ Membrane Filter composed of mixed cellulose esters (MCE) membrane, hydrophilic.

Pore Size | 0.65 μm |
---|---|
Disposable | Reusable |
Flow Rate | 140 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Color | White |
Material | MCE |
Filter Type | Membrane Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm

MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.

Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.45 μm |
Disposable | Reusable |
Flow Rate | 60 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Material | MCE |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |