Square or rectangle cuvets and cells hold a sample, often a substance dissolved in a solution, and are placed in a spectrophotometer for testing. A beam of light is passed through the sample to determine absorbance, transmittance, or fluorescence intensity, polarization and lifetime. Glass cuvets and cells are recommended for routine ultraviolet and visible region work, while quartz windows are available for transmissions from ultraviolet through far infrared. Quartz cells are noted for their durability compared to plastic or regular glass.
Material
- (5)
- (1)
- (1)
- (1)
- (2)
- (2)
- (5)
- (2)
- (11)
- (14)
- (1)
- (1)
- (28)
- (5)
- (1)
- (34)
- (2)
- (4)
- (4)
- (1)
Type
- (20)
- (2)
- (2)
- (1)
- (17)
- (1)
- (1)
- (3)
- (4)
- (1)
- (4)
- (3)
- (5)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (4)
- (3)
- (1)
- (4)
- (1)
- (1)
- (8)
- (5)
- (2)
- (3)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
Capacity (Metric)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (7)
- (2)
- (1)
- (1)
- (4)
- (3)
- (1)
- (2)
- (2)
- (5)
- (1)
- (8)
- (16)
- (1)
- (4)
- (18)
- (2)
- (2)
- (3)
- (2)
- (2)
- (1)
- (3)
- (3)
- (1)
For Use With (Equipment)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (3)
- (14)
- (6)
- (21)
- (23)
- (2)
- (12)
- (2)
- (2)
- (1)
For Use With (Application)
- (9)
- (5)
- (8)
- (2)
- (5)
- (6)
- (1)
- (1)
- (4)
- (2)
- (2)
- (16)
- (33)
- (1)
- (5)
- (1)
Filtered Search Results
Products from some of our suppliers do not display in filtered search results. Please
clear all filters
to see these products.

1
–
15
of
666
results
Fisherbrand™ Absorption Quartz Macro Rectangular Cells with PTFE Stopper
Fit standard spectrophotometer cell holders

Fisherbrand™ Fluorescence Rectangular Cells: Macro Cells With PTFE Lids
Fit standard spectrophotometer cell holders

Height (Metric) | 45 mm |
---|---|
Type | Macro Fluorescence Cell |
Shape | Rectangle |
Path Length | 10 mm |
For Use With (Equipment) | Standard Spectrophotometer Cell Holder |
Capacity (Metric) | 3000 μL |
Material | Quartz |
For Use With (Application) | Transmission from far ultraviolet through the infrared |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Wavelength Range | 200 to 2500 nm |
Width (Metric) Interior | 10mm |
Fisherbrand™ Absorption Ultra Micro Rectangular Cells with PTFE Lid
Fit standard spectrophotometer cell holders

Height (Metric) | 45 mm |
---|---|
Type | Ultra-micro Absorption Cell |
Shape | Rectangle |
Path Length | 10 mm |
For Use With (Equipment) | Standard spectrophotometer cell holder |
Quantity | Ea., 8 Ea./Cs. |
Material | Quartz |
For Use With (Application) | Transmission from far ultraviolet through the infrared |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Wavelength Range | 200 to 2500 nm |
Width (Metric) Interior | 2mm |
Fisherbrand™ Fluorescence Rectangular Cells: Micro Cells With PTFE Lids
Fit standard spectrophotometer cell holders

Height (Metric) | 45 mm |
---|---|
Type | Micro Fluorescence Cell |
Shape | Rectangle |
For Use With (Equipment) | Standard spectrophotometer cell holder |
Material | Quartz |
For Use With (Application) | Transmission from far ultraviolet through the infrared |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Wavelength Range | 200 to 2500 nm |
Fisherbrand™ Quartz Cuvette with PTFE Stopper
Contains quartz windows for transmission from far ultraviolet through the infrared.

Disposable | Single-use |
---|---|
Height (Metric) | 45 mm |
Path Length | 10 mm |
Length (Metric) | 12mm |
For Use With (Equipment) | Spectrophotometers, Fluorometers and Nephelometers |
Quantity | 500 Case |
For Use With (Application) | For assays in visible spectral range, accuracy throughout UV/Visible range |
Width (Metric) | 12 mm |
Fisherbrand™ Semi-Micro Cuvette with PTFE lid
Contains quartz windows for transmission from far ultraviolet through the infrared.

Fisherbrand™ Fluorescence Rectangular Cells: Macro Cell With PTFE Stopper, 4 Clear Windows
Fit standard spectrophotometer cell holders

Fisherbrand™ Absorption Quartz Micro Rectangular Cells with PTFE Lid
Fit standard spectrophotometer cell holders

Fisherbrand™ Absorption Macro Rectangular Cells with PTFE Lid
Fit standard spectrophotometer cell holders

Type | Macro Absorption Cell |
---|---|
Shape | Rectangle |
For Use With (Equipment) | Standard Spectrophotometer Cell Holder |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Width (Metric) Interior | 10mm |
Fisherbrand™ Absorption Quartz Semi Micro Rectangular Cells with PTFE Lid, w/PTFE lid
Fit standard spectrophotometer cell holders

Height (Metric) | 45 mm |
---|---|
Type | Semi-micro Absorption Cell |
Shape | Rectangle |
Path Length | 10 mm |
For Use With (Equipment) | Standard Spectrophotometer Cell Holder |
Capacity (Metric) | 1000 μL |
Material | Quartz |
For Use With (Application) | Transmission from far ultraviolet through the infrared |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Wavelength Range | 200 to 2500 nm |
Width (Metric) Interior | 4mm |
Fisherbrand™ Absorption Quartz Micro Rectangular Cells with PTFE Lid
Fit standard spectrophotometer cell holders

Includes | 2 clear windows |
---|---|
Type | Micro Absorption Cell |
Shape | Rectangle |
Path Length | 10 mm |
For Use With (Equipment) | Standard Spectrophotometer Cell Holder |
Quantity | 2/Pk., 8 Pk./Cs. |
Material | Quartz |
For Use With (Application) | Transmission from far ultraviolet through the infrared |
Width (Metric) | 12.5 mm |
Closure Material | PTFE |
Wavelength Range | 200 to 2500 nm |
Width (Metric) Interior | 2mm |
Fisherbrand™ Absorption Macro Rectangular Cells with PTFE Lid
Fit standard spectrophotometer cell holders

Disposable | Single-use |
---|---|
Path Length | 10 mm |
For Use With (Application) | DNA, RNA, Protein Analysis, Molecular Biology |
Wavelength Range | 230 to 900 nm |
Eppendorf™ UVette™ Cuvets

An alternative to the expensive, breakable quartz cuvets traditionally required for use at UV wavelengths

Disposable | Single-use |
---|---|
Path Length | 10 and 2 mm |
For Use With (Equipment) | Biophotometer, Spectrophotometer |
Material | UV-transparent Plastic |
Wavelength Range | 220 to 1600 nm |